制冷压缩机,它是冷凝机组的核心部分,说白了它就是一个*制冷剂的一个压力循环泵!看似简单但是它却是整个系统的心脏,制冷循环得以正常运行,都是它的功劳,你不要小看它,这东西学问大着呢!说点*基本的吧,压缩机分为高中低温,现在多数厂家生产的都是中高温,或者中低温兼容型的,也有极少数是高中低温兼容的,在选用的时候一定要根据实际需要结合库温合理选配只有这样才能达到*节能,打个比方就以上表中的制冷机组为例做一下对比来说明一个误区,看一下BFS201在冷凝温度30度蒸发温度-20度时的制冷量是21.8千瓦,在相同的工况下BFS301的制冷量是47.8千瓦,30HP的机器制冷量比20HP的大出一倍还多!这是个什么概念?这就是说在这种工况下,用两台这样的中温20HP机组制冷量还没有一台30HP低温机组制冷量大!这就是设备选型的重要性!
外转子风机,是一种低噪音的新型风机,被传得神乎其神!好东西呀,在小功率的冷凝器以及蒸发器上有不错的表现!至于风量吗!似乎还有点不尽人意,不管怎么说它的确是一种改良的产品,相信在不远的将来会有更广泛的应用,
Expansion valve is the bottleneck of refrigeration system, its selection is very important, it is no exaggeration to say whether a system can work well and efficiently it plays a decisive role, the common expansion valve is divided into internal balance and external balance, internal Balance Expansion Valve is suitable for s*ll evaporation resistance system, external balance expansion valve is suitable for large evaporation resistance system, expansion valve parameters should be selected according to the evaporator cooling capacity! In theory, the expansion valve cooling capacity should be slightly greater than the evaporator cooling capacity, but now the finished evaporator area generally shrink, especially the miscellaneous ceiling fan shrinkage problem is more serious! So in the choice of expansion valve should be considered when the problem, because the expansion valve refrigeration than the evaporator cooling capacity of more than 20% is a hidden danger! But this should be based on the actual situation of equipment to do some random adjustment, expansion valve selection, or s*ll are not good, this range should be well controlled, cooling capacity *tching is the ulti*te goal! It is necessary to esti*te the actual area and the actual refrigeration capacity of the evaporator to select the expansion valve. If the evaporator chooses a large refrigerant, it will evaporate pre*turely, the refrigeration efficiency will decrease, and the degree of superheat will increase, that is, it will increase the dry consumption of food, and it will be disadvantageous to the cooling of the compressor, evaporator selection of s*ll, and the risk of liquid hit, so in the selection of *terials must choose regular *nufacturers of high-quality products! Refrigeration compressor, it is the core of the condensing unit, it is a recovery of refrigerant pressure cycle pump! It seems * but it is the heart of the whole system, the refrigeration cycle is nor*l operation, it is a credit to it, you do not underesti*te it, this thing big knowledge! Let's talk about the most basic, the compressor is divided into high, medium and low temperature. Most *nufacturers now produce medium and high temperature, or medium and low temperature compatible, and very few are high, medium and low temperature compatible, in the selection and use of refrigeration units, it is necessary to combine the actual needs with the rational selection of the temperature of the storeroom only in this way can we achieve high efficiency and energy conservation. For example, let's take the refrigerating units in the above table as an example to *ke a comparison to illustrate a misunderstanding, see BFS201 in the condensation temperature 30 degrees evaporation temperature-20 degrees of the refrigeration capacity is 21.8 kw, in the same operating conditions BFS301 refrigeration capacity is 47.8 kw, 30 HP *chine cooling capacity than 20 HP more than double! What kind of a concept is that? This means that in this wo*ng condition, with two such 20HP middle temperature refrigeration unit is not a 30HP low temperature unit refrigeration capacity! This is the importance of equipment selection! External Rotor Fan, is a new type of low-noise Fan, has been legendary! Good thing, in the s*ll power of the condenser and evaporator has a good perfor*nce! As for the air volume! It seems a bit unsatisfactory. In any case, it is indeed an improved product, and I believe it will be used more widely in the near future,